|
Almost twenty five years have passed since Biodex introduced the
world's first multi-mode computerized robotic dynamometer.
That event and subsequent "firsts" have
made the Biodex dynamometer the choice in the most distinguished
clinics and research facilities around the world.
Sports and orthopedic medicine, pediatric medicine,
neurorehabilitation, older adult medicine, industrial medicine,
and researchers depend on Biodex to provide consistent, accurate,
objective data. Objective data that provides the best outcome for
their patients... objective data that supports their research...
objective data that separates their facility from the rest.
Our 200 employees strive to keep Biodex at the forefront in
innovation, effectiveness, efficiency and reliability. That's
why so many world class facilities depend on Biodex.
Links
to Premiere Users
Special Announcement
Biodex joins forces to provide more effective FCE solution
Read more
The fastest way to identify, treat and
document the physical impairments that cause functional limitations.
- New advanced dynamometer technology
for greater performance
- Redesigned seat accommodates athlete to pediatric applications
- New software interface, no other system is faster or easier to use
- New software features include:
- End by % of fatigue in Biofeedback, an exercise bout can be completed when the work for a repetition has dropped below a threshold (such as percentage of work)
- Rehabilitation Progress Report that plots strength, pain, ROM and other defined measurements...and much more
- New touch-screen… see it, select it,
adjust it…
- it’s that simple
- New simplified patient positioning with
on-screen audio and visual aids
- Reduced floor space
- Improved Work Simulation exercises
- Wider Range of Normative Data athlete to pediatric
- Expanded after-sale support, installation
and continuing education programs
Combine the art and science of rehabilitation
The Biodex System
4 continues to offer pioneering breakthroughs in neuromuscular
testing and rehabilitation technology. Biodex assessments of physical
impairments provides patients a fast, effective, documented return
to function. The Biodex System 4 is unusually sensitive to your
patient's limits. Progressive
and interactive features keep you in complete control. Dynamic
and static muscle loading environments provide unlimited combinations
of technique and application.
Isokinetic Resistance Mode
- The Isokinetic Resistance mode for
testing and rehabilitation is totally accommodating throughout
the entire range of motion. Biodex's unique impact-free
acceleration and deceleration eliminates joint trauma, allowing
patients to exercise and be tested at more functional speeds.
Resistance continuously matches effort, accommodating to variations
in patient force output due to weakness, pain or fatigue at specific
points in the individual's range
of motion.
- Research along with over 25 years of clinical
application has demonstrated that isokinetic resistance is a
safe, objective means to quantify physical impairments with a
high correlation to function. Isokinetic testing is the standard
for muscle and joint assessment.
- Applied torque response ensures that the patient's
limb velocity increases or decreases in proportion to the torque
applied during acceleration and deceleration, enabling neuromuscular
control measurements.
- Choose concentric and eccentric contractions
to perform isolated polymetric exercises.
- Concentric torque up to 500 ft-lb (680 Nm) and eccentric torque
up to 400 ft-lb (542 Nm) accommodates the demands of high performance
athletes and sports medicine researchers.
Reactive Eccentric Mode
- The Reactive Eccentric mode for submaximal
neuromuscular re-education in the early phases of rehabilitation
- The
System 4 responds only to the patient's force
output. To initiate movement, the patient must produce and maintain
a pre-determined minimum amount of force. This loads the muscles
surrounding the joint, producing a pre- load, thus stabilizing
and protecting the joint.
- Eccentric torque up to 400 ft-lb (542
Nm)
- Accommodates the demands of today's athletes and sports
medicine researchers.
Passive Motion Mode
- The Passive Motion mode is a multi-function
modality. Unique control properties allow for early intervention
in all patients throughout all phases of rehabilitation.
- Torque
limits can be set as low as .5 ft-lb (.7 Nm). If a torque limit
is exceeded during an eccentric contraction, the System stops.
Once the patient's torque output drops below
the prescribed limit, movement is allowed. This unique capability
allows patients to work safely at definitively prescribed sub-maximal
force levels while combining isometric, concentric and eccentric
contractions for:
- decreasing joint effusion
- increasing range of motion
- developing strength
- Passive speeds can be set as low as .25 degree
per second and as fast as 300 degrees per second. The very slow
speeds allow for overcoming the natural stretch reflex. Ideal
for proprioceptive testing in early stages of rehabilitation.
- Biodex
software includes specific protocols for active and passive joint
repositioning.
- Higher speeds in passive mode are ideal for active
assistive exercise.
Isometric Mode
- The Isometric mode is commonly used pre and post
operatively or when pain associated with motion is a factor.
Isometric contractions are effective at developing strength and
decreasing joint effusion while avoiding painful points in the
range of motion.
- Biodex
software automates the rehab process with automated multiple
angle isometric protocols. Work the agonist, antagonist or both
muscles at specified joint angles.
Isotonic Mode
- The Isotonic mode allows velocity to vary while
providing inertia-free constant force and concentric or eccentric
muscular contractions.
- Higher performance:
- Isotonic force to as low as .5 ft-lb (.7 Nm) = 6 inch pound;
and as high as 400 ft-lb (542 Nm)
- Allows for functional task simulation
when using work simulation tools, e.g. turning a doorknob.
- Because
the force is selected, the Isotonic mode also provides protective
pre-loading of the joint prior to movement.
- Ideal for work simulation. Constant
force muscle loading is considered functional, as natural activities
normally involve moving a constant weight object at varying velocities.
Enjoy complete freedom in planning the mode
and level of clinician interaction that works best for each patient.
Touch panel controls give clinicians the hands-on ability to adjust
torque, speed, range of motion and other clinical parameters in
real time.
The Biodex System 4 also allows clinicians
the option to select automated test and exercise sessions. Any
sequence of modes can be employed automatically.
Customized Motor Control
The Researcher's Toolkit Software
(optional) allows for advanced specialized system control. Ideal
for researchers investigating neuromuscular performance.
Fast and easy to use
What's the best piece of equipment? The one
that’s used the most. System 4 makes a point of being easy
to use for all skill levels, bringing the clinical advantages
of this technology to every application.
- New Touch Screen for quick, easy operation.
See it, select it, adjust it. It’s that simple.
- Advantage Software™
In today’s regulated environments, accurate and timely
data collection and documentation are absolutely essential.
- Positioning
set-ups are as simple as turning the dynamometer
and chair to the labeled joint pattern.
- Easy-to-follow wizards guide the inexperienced
user through the software while the Windows® based application
is flexible for the advanced user.
- Innovative,
on-demand action videos demonstrate exercise and test patterns – so
there is no forgetting how to set up!
Strategically expandable
To remain competitive in today's dynamic marketplace,
you need to be adaptable. To be adaptable, you need equipment that
can keep pace with progressive thinking and innovative therapies.
You need dependable, versatile tools that give you the means to
take on new challenges and extend capabilities. You need a device
that can be used to test and rehabilitate patients ranging from
the most frail to world class athletes.
Communicate need, progress and outcome
Biodex Objective Data helps you communicate need,
progress and outcome clearly and accurately. Easy to read and interpret
color graphic reports are produced
with normative data. Graphic reports and narrative letters compare
patient’s status to normative data for all joints. Data legends
and on-screen editing helps communicate the information in simple
terms for patients, doctors, third party payers and employers.
The Biodex System 4 offers a level of performance,
accuracy, and safety that remains unmatched. Not surprisingly,
Biodex equipment marks the highest correlation coefficients for
reliability, accuracy, validity and repeatability - another reason
why so many clinicians put their trust in Biodex.
 |
|
 |
| 840-000 |
System
4 Quick-Set |
|
Export models available
|
|
|
|

|
The Biodex System 4 Pro fully accommodates a wide variety
of positions and exercises. It features a positioning
chair with 360 degrees of rotation, motorized seat
height adjustment and superior stabilization.
Specifications
|
|

Biodex System 4 Quick-Set features a fixed-height positioning
chair with 360 degree rotation and front/back travel
for fast, easy patient setups that ensure maximum patient
stabilization.
Specifications |
|
 |
| New
York Giants
Dallas Cowboys
San Francisco 49ers
Miami Dolphins
New York Jets
New York Mets
Denver Broncos
Indianapolis Colts
Florida Marlins
New Orleans Saints
Toronto Blue Jays
Washington Capitals
Philadelphia Phillies
Los Angeles Dodgers
Chicago Bears
Montreal Expos
Cleveland Indians
Kansas City Royals
Detroit Tigers |
California
Angels
Los Angeles Lakers
St. Louis Cardinals
Chicago White Sox
Anaheim Mighty Ducks
Seattle Supersonics
Philadelphia Eagles
Pittsburgh Pirates
Kansas City Chiefs Pittsburgh Steelers
Carolina Panthers
Jacksonville Jaguars
Los Angeles Clippers
Orlando Magic
Washington Wizards
Atlanta Falcons
Texas Rangers
Houston Rockets |
|
| You
don’t have to be a superstar to be treated like one. |
 |
1. Healing constraints
and Proving Need In Passive Mode, gentle range of motion exercise
can facilitate the healing process and restore normal range
of motion necessary for function. Isometric mode allows safe
comfortable strengthening and testing at specified angles
that are safe for both your pre-operative and post-operative
patients.
|
2. Controlling Joint Effusion / Inflammation
Utilizing
the Passive mode with other modalities allows the structures
around the joint to work as a pump to move blood, lymph and
other waste products out of the joint. The Biodex System 4
has the capability to move the limb as slow as .25 degrees
per second and with force capabilities as low as .5 ft-lbs. |
3. Restoring Range
of Motion
Controlling the System 4 through the GUI interface in Passive
Mode allows range of motion to be restored by gradually increasing range of motion
"on the fly" in specified direction, appropriate speeds and safe torque levels. |
4. Restoring Strength and Proving Progress
Isometric,
active assistive, sub maximal concentric and submaximal eccentric
contractions are early strengthening techniques that are available to the System
4 user. More progressive maximal concentric, eccentric contractions
are available in Isokinetic, Isotonic, Passive and Reactive Eccentric modes.
All of these modes are also suitable for testing and delineating a documentable
progression of muscular strength, endurance and joint position sense. |
5. Restoring Function
Isokinetic concentric / concentric mode allows for safe exercise at speeds
which approximates function. Impact and inertia free Isotonic mode allow muscle
to contract exactly as they would performing during Functional activities.
Joint position sense, muscular acceleration and deceleration are also activities
that are addressed with the Biodex System 4. |
6. Proving Outcome
All five modes are available
to objectively assess isolated joint muscular strength and
endurance. Report parameters are comparable to normative data.
Progress Reports and Exercise Summary Reports are available
to track available test criteria such as pain, range of motion,
strength, and
other customizable parameters. |
 |

Used and reconditioned Biodex Multi-Joint
Systems are available directly from Biodex Medical
Systems!
Contact
us for our current listings.
|
 |

Contact Biodex first at 1-800-224-6339
(in NY or Int'l.1-631-924-9000) or Contact
us for
a quick quote! |
|
|