Home Nuclear Medicine
Tec-Control Chromatography
description   price

For radiopharmaceutical quality control

Tec-Control Chromatography tests the radiochemical purity of specific Tc-99m-labeled radiopharmaceuticals. The accompanying chart shows which strips and solvents are
required to perform each individual test. Some solvents must be purchased separately
(see Sigma-Aldrich chart) due to hazardous material shipping restrictions.

Detailed instruction manuals are packaged with each strip container, although our
Radiopharmaceutical QC Procedure Manual (151-000) explains paper chromatography
in greater detail.

TEC-CONTROL ALUMINUM BREAKTHRU KIT

Simple 3-step procedure


The Aluminum Breakthru Kit provides a rapid, easy and inexpensive way to test aqueous
solutions, particularly pertechnetate generator eluate, for trace quantities of aluminum.
Aluminum forms an intense red precipitate with the indicator paper, and the intensity of the
color is directly proportional to the amount of aluminum in the solution. The USP allows a
concentration of aluminum ion in an injection ≤10 micrograms per milliliter (10 µg/ml) in
technetium 99m eluate prepared from Molybdenum 99 formed as a result of uranium fission.

Simple Procedure:

1. Place a drop of the eluate or solution to be tested on the indicator paper.
The best procedure is to form a hanging drop using a 19-22G needle.
2. Place a drop of the standard aluminum solution on the indicator paper.
Use the same size drop.
3. Compare the intensity of the red spot formed. If the eluate spot is less intense
than the standard solution, the eluate contains less than 10µg/ml aluminum.

 

150-780 Chromatography Kit, Tec-Control
Aluminum Breakthru Kit includes:
Aluminum standard, 5 ml, 10 ug/ml,
50 indicator strips and manual
$65.00
151-000 Procedure Manual,
Radiopharmaceutical QC
16.95


References:

Miniaturized Chromatographic Quality-Control Procedures for Tc-99m Radiopharmaceuticals;
A. Michael Zimmer and Dan G. Pavel, Journal of Nuclear Medicine, Vol. 18/12, Dec. 1977, pg. 1230.
Technical Parameters Associated with Miniaturized Chromatography Systems; Raimund A. Taukulis,
A. Michael Zimmer, Dan G. Pavel and Bhupendra A. Patel, University of Illinois Medical Center,
Chicago, Illinois, Journal of Nuclear Medicine Technology, Vol. 7/1.

 




QC manual

Radiopharmaceutical

QC Manual


This 90-page manual explains Paper Chromatography, a QC method for evaluating the radiochemical purity of currently used Tc-99m-labeled radiopharmaceuticals. Procedures are quick and easy to use, a simple quality control solution for any nuclear medicine department.


RADIOPHARMACEUTICAL SOLVENT(S) REQUIRED* STRIPS REQUIRED
Aluminum Breakthru 150-781 150-782
Bicisate (Neurolite™) Ethyl Acetate 99.% 150-130
Diphosphonate Acetone (HPLC Grade), Distilled H2O 150-001 & 150-005
Disofenin (Hepatolite™) 150-160, Distilled H2O 150-122 & 150-125
DMSA Acetone (HPLC Grade), 150-025
DTPA Acetone (HPLC Grade), Distilled H2O 150-001 & 150-005
Exametazine (Ceretec™) Ethyl Acetate 99.% 150-130
Glucoheptonate Acetone (HPLC Grade), Distilled H2O 150-001 & 150-005
HDP Acetone (HPLC Grade), Distilled H2O 150-001 & 150-005
MAA Acetone (HPLC Grade), 150-001
MAG3 (Mertiatide™) Acetone, (HPLC Grade),
Chloroform 99.8%
Tetrahydrofuran 99+%
150-951 & 150-952
MDP Acetone (HPLC Grade), Distilled H2O 150-001 & 150-005
Mebrofenin (Cholotec™) 150-160, Distilled H2O 150-122 & 150-125
Pyrophosphate Acetone (HPLC Grade), Distilled H2O 150-001 & 150-005
Sestamibi (Cardiolite™ and Miraluma™ Ethyl Acetate 99.% 150-991
Sulphur Colloid Acetone (HPLC Grade) 150-001
Tc-99m (reduced) Acetone (HPLC Grade), 150-001
Tc-99m Monocolonal Antibodies 0.9% Saline 150-771
Tetrofosmin (Myoview™) Ethyl Acetate 99.% 150-971
In-111, Octreotide (Octreoscan™) 150-773 & 0.9% Saline 150-771 **
In-11 Monocolonal Antibodies 150-773 & 0.9% Saline 150-771 **
In-111/Y-90 Zevalin™ 150-773 & 0.9% Saline 150-771
I-131 Monoclonal Antibodies
And Neutrospec™
0.9% Saline 150-771

* See Sigma-Aldrich product matrix for solvents.
** Note: A Well Plate is suggested to perform QC on these radiopharmacuticals
  Contact Fisher Scientific Corp. 800-766-7000 / www.fishersci.com / Item #14-245-71


Chromatography Strips
150-001 Strips, RED, 50/pkg $33.00
150-005 Strips, BLACK, 50/pkg 43.00
150-025 Strips, YELLOW, 50/pkg 54.00
150-122 Strips, ORANGE, 50/pkg 43.00
150-125 Strips, LIGHT BLUE, 50/pkg 43.00
150-130 Strips, GOLD, 50/pkg 50.00
150-771 Strips, DARK GREEN, 50/pkg 45.00
150-951 Strips, LIME, 50/pkg 45.00
150-952 Strips, PEACH, 50/pkg 45.00
150-971 Strips, TEAL, 50/pkg 50.00
150-991 Strips, PINK, 50/pkg 50.00
150-782 Strips, ALUMINUM, 50/pkg 35.00

Chromatography Solvents
150-160 Solvent, 20% Sodium Chloride, 30 ml $25.00
150-773 Solvent, DTPA, 5 ml 25.00
150-781 Solvent, Aluminum Standard, 5 ml, 10 µg/ml 35.00

Related Items:

150-960 Developing Vials, 10 ml, 288/case
(used for all Tec-Control testing)
$250.00
150-961 Developing Vials, 5 ml, 144/case
(used for Sestamibi & Tetrofosmin)
100.00
066-533 Forceps, Curved, Locking, 9.5" l
(24.1 cm)
32.00
066-535 Forceps, Straight, Locking, 9.5" l
(24.1 cm)
32.00
066-536 Forceps, Curved, Non-Locking,
13.5" l (34.3 cm)
48.00

Send for More Information
Conditions of Purchase
 
Tec-Control Solvent Vendor:
Sigma-Aldrich Chemical Company
800-558-9160 / www.sigmaaldrich.com


Note: Customers outside the US should visit Sigma-Aldrich web site
to locate a regional office.
Solvent Description Vendor Part #
Acetone HPLC Grade 27072-5
Ethyl Acetate 99.5% ACS Reagent 31990-2
Chloroform 99.8% ACS Reagent 31998-8
Tetrahydrofuran 99+% ACS Reagent 36058-9

description   price
 
Home Nuclear Medicine

 
Home About Biodex Support Services Contact Biodex Terms of Use