Home Nuclear Medicine Dose Calibrators PET
Atomlab™ 100 Dose Calibrator
features   description   specifications   price   testiminials   physics test reports    

Designed for facilities receiving unit doses including PET and Beta

  • All functions microprocessor controlled
  • Ultra-fast response
  • Automatic range selection; ranges up to 9.999 Curies of Tc-99m or 2.5 Curies of F-18
  • Pre-programmed for the most commonly used radionuclides
  • Display in Curies or Becquerels
  • Automatic background subtraction and zeroing at the touch of a button
  • Remote ionization chamber with .25" (.64 cm) lead shielding and 10-foot (3.05 m) cable
  • Self-diagnostic software
  • Daily constancy isotope keys
  • Electronic power supply (no battery in chamber)
  • Industry exclusive two-year warranty
  • RS-232 bi-directional serial communications port
  • ETL to UL 3101-1 and cETL to CAN/CSA C22.2 No. 1010.1-M92

The Atomlab 100 provides fast, accurate radionuclide activity measurements with performance that easily surpasses the most stringent regulatory requirements. The unit is simple to operate. There are 13 isotope selection keys, ten are pre-programmed for the most commonly used radionuclides, and three are user defined. There are 94 isotope-specific dial values listed in the manual, including Y-90 and Sr-89. Any key can be reprogrammed by the user for a desired isotope.

Activity is displayed on a LED readout in either Curie or Becquerel units. Background correction and zero adjustment are performed at the touch of a button. Range selection is automatic. Activity measurements are performed by a microprocessor controlled electrometer located within the detector assembly of the ionization chamber.

The chamber is shielded with .25" (.64 cm) lead. It can be located up to ten feet away from the display unit. Chamber bias is generated within the display unit by an electronic high voltage supply, eliminating the need for expensive battery changes.

The RS-232 port enables the Atomlab 100 Dose Calibrator to communicate with most commercially available nuclear medicine management systems. An industry exclusive two-year warranty is standard.


Specifications

  • Isotope Selection Keys: Ten pre-programmed — Tc-99m, Tl-201, Mo-99; I-123; Xe-133,
    Ga-67, In-111, I-131, Cs-137, and Co-57; three additional keys for user-defined isotopes
  • Activity Range: 0.01 µCi to 9999 mCi (.001 MBq to 399.9 GBq) of Tc-99m
  • Energy Range: 25 keV to 3 MeV photons
  • Response Time: One second for doses greater than 2 mCi; three seconds
    between 200 µCi and 2 mCi; 3-30 seconds below 200 µCi
  • Detector Linearity: ±1% or 0.2 µCi, whichever is greater
  • Electrometer Linearity: ±1% or 0.2 µCi, whichever is greater
  • Electrometer Accuracy: ±1% or 0.2 µCi, whichever is greater
  • Overall Accuracy: ±3% or 0.3 µCi, whichever is greater; overall accuracy is affected by such factors as the accuracy of the specific source calibration, geometric variations due to sample volume or configuration, detector linearity, electrometer accuracy and readout accuracy
  • Repeatability: ±0.3% above 1 mCi short term (24 hr); 1% long term (one yr);
    exclusive of background
  • Digital Calibration Dial: Four-digit LED dial display with increment/decrement keys to change the value; range is from 0.1 to 999
  • Detector: Well-type pressurized ionization chamber, with Argon fill gas; well opening 2.75" (7 cm), well depth 10.5" (26.7 cm)
  • Detector Shielding: .25" (6.3 mm) lead on all sides except top well opening;
    supplementary shielding available
  • Chamber Bias: 340 volt electronic power supply Environmental Operating Conditions:
    - Temperature: 0-40° C
    - Humidity: 0-90% rh, non-condensing
  • Power Requirements: 100 to 120 VAC @ 1/2A; 200 to 240 VAC @ 1/4A z
  • Line Frequency: 50/60 Hz; detachable line cord; built-in EMI filter and transient suppression
  • Detector and Interface Cables: 10' (304.8 cm) long, six conductor cables
    (two carry power, one is chassis ground, three carry serial data for digital I/O);
    ends terminated with AMP Mate-n-Lock connectors, white with hooded strain relief
  • Display Unit:
    - Dimensions: 12" w x 14.3" depth x 3.75" h (30.5 x 36.3 x 9.5 cm)
    - Weight: 6 lb (2.7 kg)
  • Detector Unit:
    - Dimensions: 7.5" w x 7.5" depth x 16.25" h (19 x 19 x 41.3 cm)
    - Well I.D.: 2.75" dia x 10.5" h (7 x 26.7 cm)
    - Well I.D. with Liner: 2.5" dia x 10.25" h (6.35 x 26 cm)
    - Lead Shielding: .25" thick (.63 cm)
    - Weight: 35 lb (16 kg)
  • Approvals: ETL to UL 3101-1 and cETL to CAN/CSA C22.2 No. 1010.1-M92

086-250 Dose Calibrator, Atomlab™ 100,
115 VAC
Includes RS-232 port, vial/syringe dipper and well insert.
$5,600.00
086-258 Dose Calibrator, Atomlab™ 100,
230 VAC
Includes RS-232 port, vial/syringe dipper and well insert.
5,600.00

Related:

086-301

Dose Calibrator Shielding Rings,
Interlocking, 2" lead
For additional protection from
high energy activity.

$2,300.00
086-423 Moly Shield, Vial, .3" lead 125.00
086-435 Moly Shield, Syringe, .3" lead 425.00
086-509 Lineator 495.00

Replacement:

086-242 Vial/Syringe Dipper $70.00
086-241 Well Insert 70.00

Send for More Information
Conditions of Purchase

  atomlab 100 dose calibrator
  Click here for
more information

Related Products
Lineator
Reference Sources

Physics Tests
Quality Assurance Testing (pdf 148kb)
Alphabetical Listing of Isotopes (pdf 284kb)
[308] ACCURACY OF F-18
CALIBRATION SETTINGS IN COMMERCIAL
DOSE CALIBRATORS

[1520] MEASURED ACTIVITY OF
F-18 FDG UNIT DOSES IN A CLINICAL
MOBILE PET/CT ENVIRONMENT

Dose Calibrator Performanc
Evaluation of Atomlab 100
Results on the Tests Performed
on the New Dose Calibrator
from Biodex Medical Systems

Atomlab 100Dose Calibrator
The Atomlab 100 Dose Calibrator shown on the PET Unit Dose Cabinet for complete space efficiency.

For facilities seeking full reimbursement, now is the time to pursue ICANL accreditation. Dose Calibrators are among their equipment recommendations as presented in The Standards.
Visit www.icanl.org for details.

 


features   description   specifications   price   testiminials   physics test reports  
 
Home Nuclear Medicine Dose Calibrators PET

 
Home About Biodex Support Services Contact Biodex Terms of Use