| With built-in GM Gamma
Detector for continuous monitoring
- Detects gamma radiation
- LOW and HIGH alarms with yellow and red lights,
adjustable audible tones
- 0.1 mR/hr - 1000 mR/hr or 1 µSvh - 9999 µSv/h
- Detector
failure light and tone to signal detector overload or instrument failure
- Threshold
adjustment from 2 to 100 mV
- Battery continuously trickle charges when
unit is operating and connected to wall current
- Low battery warning
The Digital Area Monitor with built-in GM Gamma Detector
provides continuous gamma radiation monitoring of rooms where radionuclides
are received, stored, or dispensed, and in waste management areas where
there is the possibility of radioactive contamination. The monitor is
wall-mountable.
- Internal Detector: Halogen quenched GM gamma
detector, sensitivity: 1000 cpm/mR/hr (Cs-137 gamma), energy
response (60 keV - 3
MeV): within ±25% of true value
- Display: Four-digit LED display
with 0.8" (2 cm) character
height
- Display Range: 000.0-9999
- Display Units: Available in mR/hr or µSv/h
- Linearity: Reading
within ±10% of true value with detector
connected
- Response: Typically three seconds from 10% - 90% of final
reading
- Status: (Green light) instrument functioning properly
- Alarm: Low
alarm - indicated by yellow light and slow beep (one per second)
audible tone (can be set at any point from 0.0 - 9999); high
alarm - indicated by red light and fast beep (4 per second) audible
tone (can be set at any point from 0.0 - 9999); NOTE: Audible
indicators can be configured as a single beep if desired
- Det Fail: Detector
overload, no count from detector, or instrument failure Ð indicated
by red light and audible tone (greater than 68 dB at 2 feet)
- Low
Bat: (Yellow) indicates less than two hours of battery power
remaining
- High
Voltage: Adjustable from 200 - 2500 volts
- Threshold: Adjustable
from 2 - 100 mV
- Dead Time: Adjustable to compensate for dead time
of detector and electronics (can be read on display)
- Overload: Senses
detector saturation (indicated by display reading "-OL-")
- Overrange:
Indicates radiation field being measured has exceeded counting
range of instrument (indicated by display reading "-
- - -")
- Data Output: 9 pin connector providing 5 decade logarithmic
output,
RS-232 output, signal ground connection, FAIL and ALARM signals
(current sink), and direct connection to battery and ground
- Calibration
Controls: Accessible from front of instrument
(protective cover provided)
- Power: 115 VAC; 220 VAC or battery power
- Battery Life: Typically
48 hours in non-alarm condition;
12 hours in alarm condition
- Battery Charger: Battery is continuously
trickle charged when instrument is connected to line power and
turned on
- Battery Dependence: <3% change in readings
to battery endpoint
- Construction: Wall mount aluminum housing with ivory polyurethane
enamel paint
- Dimensions: 7.4" h x 9.7" w x 2.5" depth
(18.7 x 24.6 x 6.4 cm)
- Weight: 6.7 lb (3 kg)
 |
| 051-275 |
Monitor, Digital Area,
115 VAC
Includes: Built-in GM Gamma Detector
display in mR/hr |
$1,295.00 |
|
 |
| 051-279 |
Monitor, Digital Area,
230 VAC
Includes: Built-in GM Gamma Detector
display in mR/hr |
1,295.00 |
|
 |
| 051-273 |
Monitor, Digital Area,
230 VAC
Includes: Built-in GM Gamma Detector
display in µSv/h |
1,295.00 |
|
|
|

Digital Area Monitor - available in mR/hr
or µSv/h |