Home Nuclear Medicine Radiation Detection
Digital Entrance/Exit Area Monitor
description   specifications   price

For facility entrances, waste management areas, inter-department corridors

  • Detects gamma radiation
  • 0.1 mR/hr - 1 R/hr range
  • Digital display
  • Includes two wall-mount NaI (Tl) scintillation detectors with enclosures and cables
  • Separate LOW and HIGH alert/alarm with yellow/red lights, adjustable audible tones
  • Detector failure light and tone to signal detector overload or instrument failure
  • Low battery warning
  • Threshold adjusts from 2 to 100 mV
  • Battery continuously trickle charges when unit is operating and connected to wall current

This Area Monitor serves as a radiation sentry/alert for building entrances, halls, and doorways. Equipped with a pair of NaI (Tl) scintillation detectors that mount on both sides of a doorway or hall, the unit continuously monitors incoming and outgoing materials and people for low-level gamma radiation. Typical applications are the monitoring of areas where waste material leaves departments or buildings, and monitoring emergency room entrances in the event of radiation-related emergencies. The Area Monitor can be set to give a visual and/or audible alert (yellow light, slow beep) when a selected background level has been exceeded, and give an alarm signal (red light, fast beep) when a selected radiation level is reached. Lights and audibles also indicate detector overload, no count from detectors, or instrument failure. A yellow LED illuminates when the battery has less than 2 hours of power remaining. The monitor is wall-mountable. Two 25-foot detector connection cables are included.


Specifications

  • Detectors (2): 3" dia x 1" thick (7.6 x 2.5 cm) shielded NAI (Tl) scintillation detectors in NEMA4x enclosures
  • Display: Four-digit LED display with 0.8" (2 cm) character height
  • Display Units: Can be made to display in µR/hr, mR/hr, R/hr, µSv/h, mSv/h, Sv/h, µrem/hr, mrem/hr, rem/hr, cpm, cps, and others
  • Linearity: Reading within ±10% of true value with detector connected
  • Response: Typically three seconds from 10% - 90% of final reading
  • Status: (green light) instrument functioning properly
  • Alarm: Low Alarm - indicated by yellow light and slow beep (one per second) audible tone (can be set at any point from 0.0 - 9999); High Alarm - indicated by red light and fast beep (four per second) audible tone (can be set at any point from 0.0 - 9999); NOTE: Audible indicators can be configured as a single beep if desired
  • Det Fail: Detector overload, no count from detector, or instrument failure Ð indicated by red light and audible tone (greater than 68 dB at 2 feet)
  • Low Bat: (yellow) indicates less than two hours of battery power remaining
  • High Voltage: Adjustable from 200 - 2500 volts
  • Threshold: Adjustable from 2 - 100 mV
  • Dead Time: Adjustable to compensate for dead time of detector and electronics (can be read on display)
  • Overload: Senses detector saturation (indicated by display reading :"-OL-")
  • Overrange: Indicates radiation field being measured has exceeded counting range of instrument (indicated by display reading "- - - -")
  • Data Output: Nine-pin connector providing five decade logarithmic output, RS-232 output, signal ground connection, FAIL and ALARM signals (current sink), and direct connection to battery and ground
  • Calibration Controls: Accessible from front of instrument (protective cover provided)
  • Power: 115 VAC; 220 VAC or battery power
  • Battery Life: Typically 48 hours in non-alarm condition, 12 hours in alarm condition
  • Battery Charger: Battery is continuously trickle charged when instrument is connected to line power and turned on
  • Battery Dependence: <3% change in readings to battery endpoint
  • Monitor Construction: Wall mount aluminum housing with ivory polyurethane enamel paint
  • Dimensions:
    - Monitor electronics unit: 7.4" h x 9.7" w x 2.5" depth (18.7 x 24.6 x 6.4 cm)
    - Detectors (each): 13" h x 17" w x 8.5" l (33 x 43 x 22 cm)
    - Connecting cables (each): 25-foot, type "C" connector
  • Weight:
    - Monitor electronics unit: 6.5 lb (2.3 kg)
    - Detectors (each): 32 lb (14.5 kg)

051-022 Monitor, Area, Entrance/Exit,
115 VAC

Includes: Two NaI (T1) Scintillation Detectors
$5,895.00
051-024 Monitor, Area, Entrance/Exit,
230 VAC

Includes: Two NaI (T1) Scintillation Detectors
5,895.00

Send for More Information
Conditions of Purchase
 

description   specifications   price
 
Home Nuclear Medicine Radiation Detection

 
Home About Biodex Support Services Contact Biodex Terms of Use